FIRE PROTECTION PREVENTATIVE MAINTENANCE

From independent consultancy to your single-source life safety vendor. We coordinate, inspect, and maintain every system in your portfolio.

Preventative Maintenance
Overwatch Shield

Your Only Fire & Life Safety Vendor

Overwatch Fire is fully equipped to manage your entire life safety systems directly. We provide licensed, professional service in Sprinklers, Alarms, Backflows, and Fire Extinguishers under one unified standard of safety.

By consolidating your site’s maintenance under our Strategic Advocacy Program, we eliminate the friction of managing multiple specialized contractors. We don't just perform the work; we manage the lifecycle of your equipment to ensure you stay ahead of the Fire Marshalβ€”not just reacting to them.

Our package plans are designed for asset managers who need predictable overhead and total compliance. Whether you are managing a single facility or a multi-site portfolio, our oversight ensures that every inspection, repair, and certification is handled with professional onsite representation and rigorous quality control.

ITM SERVICESThe Operator Path

Inspection, Testing, and Maintenance (ITM) is the mechanical foundation of life safety. While code compliance is the requirement, system readiness is the mission.

As your licensed service partner, Overwatch self-performs high-precision ITM across all major fire protection systems. We bridge the gap between regulatory mandates and real-world reliability.

THE OVERWATCH ADVANTAGE

Standard 01

Technical Transparency

We provide absolute clarity on system health. No hidden "bundled" repairs or ambiguous reportingβ€”just raw technical data and honest assessments.

Standard 02

Licensed Execution

Every inspection is performed by state-licensed technicians specialized in their respective fields (Alarms, Sprinklers, Backflow, and FEX).

Standard 03

Digital Accountability

Your compliance data is centralized and digitally tracked. Access reports, asset histories, and upcoming service cycles instantly through our portal.

Standard 04

Zero-Gap Readiness

Our goal isn't just a passed inspection; it's mechanical readiness. We ensure your systems function as intended the moment they are needed.

β˜… β˜… β˜…

FIRE SPRINKLERSystems & ITM Protocol

NFPA 25 Inspection Anatomy
Main Drain
01

Main Drain Test

Annual verification that water supply is unrestricted.

Valve
02

Valve Stewardship

Control valves must be locked and mechanically sound.

Internal
03

5-Year Internal

Deep mechanical audit to identify corrosion or debris.

TECHNICAL GALLERY KNOW YOUR COMPONENTS
Pendent
PENDENT HEAD
Downward Facing

Standard for finished ceilings. Deflects water downward.

Upright
UPRIGHT HEAD
Upward Facing

Used in mechanical rooms where exposed piping is common.

Sidewall
SIDEWALL HEAD
Horizontal Mount

Ideal for corridors where overhead piping is restricted.

Control Valve
CONTROL VALVE
System Riser

The mechanical command center. Controls water flow.

FDC
FDC
Fire Dept. Connection

Exterior inlet for fire crews to pump supplemental water.

SYSTEM ARCHITECTURE WET VS. DRY SYSTEMS

Wet Pipe System

Water is always present in the pipes. Fastest response time.

Dry Pipe System

Filled with pressurized air. Engineered for unheated areas.

BACKFLOWPrevention & Certified Testing

Protecting the public water supply through technical precision. Overwatch provides certified annual testing, mechanical auditing, and high-hazard repair across Washington State.

TESTING PROTOCOL Anatomy of a Backflow Test
Testing
01
Differential Testing

Measuring pressure drops with calibrated gauges to verify back-siphonage protection.

02
Relief Verification

Ensuring RPZ relief valves discharge correctly to prevent line pollution.

Verification
Submission
03
Digital Submission

Real-time reporting to water purveyors to clear compliance deadlines immediately.

TECHNICAL GALLERY KNOW YOUR EQUIPMENT
DCVA
DCVA
Double Check Valve

Standard protection for low-hazard lines like Fire Sprinklers and Irrigation.

RPZ
RPZ / RPBA
Reduced Pressure Zone

High-hazard protection for chemical lines. Dumps water if internal failure occurs.

Test Kit
TEST KIT
Differential Gauge

Calibrated 5-valve gauge used to measure precise pressure drops.

Enclosure
ENCLOSURE
"Hot Box"

Insulated housing designed to shield assemblies from freezing and vandalism.

HAZARD CLASSIFICATION DCVA VS. RPBA
Standard Protection

Double Check (DCVA)

Low Hazard: Used for substances that are objectionable but not a health threat.

High Hazard

Reduced Pressure (RPZ)

Critical Hazard: Relief valve dumps water if check fails, preventing backflow at all costs.

Industry Specific Compliance
NFPA
Kitchen Systems
NFPA 96 Compliance
  • Class K Mandate within 30ft
  • Verification of Hood Interlocks
OSHA
Industrial
OSHA 1910.157
  • Strict Travel Distance Limits
  • Mandatory 30-Day Quick Checks
Joint Commission
Healthcare
NFPA 99 / TJC
  • MRI-Conditional Units
  • OR Clean Agent requirements
ICC
Property Mgmt
Intl Fire Code
  • ADA Cabinet Mounting
  • Egress Safety Audits

FIRE ALARMSystems & ITM Protocol

The "Brain" of your facility's safety infrastructure. Overwatch provides comprehensive NFPA 72 inspections, smoke sensitivity testing, and emergency signal verification.

Anatomy of an NFPA 72 Test

Verify system mechanical readiness moves beyond simple visual audits. Overwatch technicians execute rigorous functional testing protocols.

Panel Calibration
01
Panel Calibration

Verifying primary power supplies and testing backup battery load capacity.

02
Sensitivity Testing

Ensuring smoke detectors activate within mandated NFPA ranges.

Sensitivity Testing
Monitoring Verification
03
Monitoring Verification

Simulating alarm signals to verify sub-60 second Central Station reception.

FACP Control Panel
FACP
Control Panel

The "Brain" of the system. Monitors inputs and triggers alarms.

Smoke Detector
SMOKE DETECTOR
Initiating Device

Automatic sensor that detects smoke particles.

Manual Pull Station
PULL STATION
Manual Activation

Allows occupants to manually trigger a general fire alarm.

ADA Horn Strobe
HORN / STROBE
Notification Appliance

ADA-compliant strobes and horns for rapid evacuation.

Thermal Heat Detector
HEAT DETECTOR
Thermal Activation

Triggers on high temps. Ideal for dusty environments.

Legacy Technology

Conventional

Hardware-based systems that divide building into generic "Zones."

Modern Standard

Addressable

Each device has a unique digital ID for instant identification.

FIRE EXTINGUISHERCompliance & Mechanical Integrity

The first line of defense. Overwatch manages the complex, multi-year mechanical lifecycles of your extinguisher fleetβ€”ensuring every unit is pressurized, certified, and ready for immediate deployment.

Anatomy of the ITM Lifecycle

While standard units follow 6 and 12-year cycles, specialized CO2 and Wet Chemical units require hydrostatic testing every 5 years.

Annual
01
Annual Inspection

Professional mechanical audit and physical tag update.

Internal
05/06
Internal Maintenance

Internal check & agent recharge. Year 5 for CO2; Year 6 for ABC.

Hydro
05/12
Hydrostatic Test

Cylinder integrity testing. Every 5 or 12 years depending on shell type.

KNOW YOUR SYSTEM FIRE EXTINGUISHER TYPES
Class A
CLASS A
Ordinary Combustibles

Wood, paper, and trash hazards.

Class ABC
CLASS ABC
Multi-Purpose Dry Chem

Standard multi-hazard unit for offices.

Class C
CLASS C (CO2)
Electrical / Server Rooms

Non-conductive agent for electronics.

Class D
CLASS D
Combustible Metals

Specialized agent for industrial metal fires.

Class K
CLASS K
Commercial Kitchens

High-heat grease fires in commercial cooking.

SYSTEM ARCHITECTURE MECHANICAL OPERATING PRINCIPLES

Stored Pressure

The standard unit where gas and agent are stored together. Requires constant pressure gauge monitoring.

Cartridge Operated

Industrial-grade units with gas in a separate external cartridge. Designed for harsh environments.

Consolidated ITM Compliance

NFPA
National Standards
NFPA 10, 25, & 72
  • Sprinklers: Annual main drain & valve audits (NFPA 25).
  • Alarms: 100% annual functional testing (NFPA 72).
  • FEX: 6/12 year internal maintenance (NFPA 10).
OSHA
Workplace Safety
OSHA 1910 / IFC
  • Mandatory 30-day checks for all life-safety equipment.
  • ADA compliant mounting for Alarms and FEX cabinets.
  • Dual-path monitoring and automatic emergency dispatch.
Joint Commission
Healthcare / TJC
NFPA 99 / EC.02.03.05
  • MRI-Conditional equipment and OR Clean Agent requirements.
  • 100% asset inventory accuracy and immediate resolution.
  • Hyper-rigorous documentation for hospital accreditation.
AWWA
Water & Health
AWWA M14 / BRYCER TCE
  • Annual testing mandates for cross-connection assemblies.
  • Mandatory digital submission to The Compliance Engine.
  • Point-of-use isolation and containment standards.